Feature:
1. Mini Design: The weather meter is a compact and highly integrated integrated sensor, which is smaller in design and equally powerful compared to traditional integrated environmental sensors.
2. Multifunction Monitoring: Measures 5 weather elements, including wind speed, wind direction, air temperature, humidity, and air pressure in a compact and lightweight design.
3. Wide Environmental Adaptability: Tested in harsh environments for temperature, waterproof, and salt spray resistance, suitable for various applications including agriculture, meteorology, forestry, and more.
4. Highly Accurate Data: Utilizes efficient filtering algorithm and special compensation technology for rain and fog weather, ensuring stable and consistent data readings.
5. Versatile Application: Ideal for wind monitoring in agriculture, meteorology, forestry, power plants, chemical factories, ports, railways, highways, and more, enabling appropriate response measures to be taken.
Specification:
Item Type: Wired Weather Meter
Product Size: Approx. 165x70mm / 6.5x2.8in
Gross Weight: 457g/16.1oz
Material: ABS, Aluminum Alloy
Supply Voltage: DC5V
Communication Type: TTL (for Modbus RTU)
Cable Length: 2 Meters
Operating Environment: 0?100percent RH, ?40 celsius to +60 celsius
Protecting Grade: IP64
Built in Sensors: Wind Speed, Wind Direction, Temperature, Humidity, Air Pressure
Widely Used: Wind Direction Measurement in Greenhouse, Environmental Protecting, Ship, Wharf, Aquaculture, Advertisement Gate, Meteorology, Ocean, Environment, Airport, Harbor, Laboratory, Industry, Agriculture and Transportation Environment.
Wind Speed: 0 to 45m/s range, start wind speed less than 0.8m/s, +/-(0.5+0.02V)m/s accuracy, 0.1m/s resolution, 40mW power consumption
Wind Direction: 0 to 359 degrees range, +/-3 degrees accuracy, 1 degrees resolution, 40mW power consumption
Atmospheric Temperature: -40 to 80 degrees C range, +/-0.3 degrees C accuracy, 0.1 degrees C resolution, 1mW power consumption
Atmospheric Humidity: 0 to 100percent RH range, +/-5percent RH accuracy, 0.1percent RH resolution, 1mW power consumption
Atmospheric Pressure: 300 to 1100hPa range, +/-0.5 hPa (25 degrees C) accuracy, 0.1 hPa resolution, 0.1mW power consumption
Sensor Total Power Consumption: <150mW
Wiring Diagram:
TTL signal output, the sensor wire sequence is defined as follows:
Red: power positive VCC
Green: power negative GND
Black: TXD
Yellow: RXD
Note: Make sure the wiring is correct before sending power.
Communicating Protocol:
All commands in the manual of weather meter are RTU protocol format commands. All have been configured at the factory, if you need to modify the protocol, refer to the relevant commands or ask for help. Baud rate 9600, 8 data bits, 1 stop bit, no check. 2 frames of data communicating interval of at least 500ms. The default address is 1, and the RTU communicating format is as follows:
Number of address bytes: 1 byte
Number of command bytes: 1 byte
Number of register address bytes: 2 bytes
Number of data bytes: N bytes
Number of CRC check bytes: 2 bytes
I.Register address:
The weather meter can integrate five modes, namely wind speed, wind direction, air temperature, air humidity, and atmospheric pressure. Each sensor has its own register address.
II.Configuration address and baud rate:
The commands to write the device address are the same for the weather meter.
III.CRC verification steps:
1. Preset the 16 bit register to hex FFFF, call this register the CRC register
2. Isolate the first 8 bit data with the lower bit of the CRC register, and put the result in the CRC register
3. Check the lowest bit by shifting the contents of the register one bit to the right (toward the lower bit) and filling the highest bit with a 0
4. If the lowest bit is 0: repeat step 3 (shift again) if the lowest bit is 1: the CRC register is iso orthogonal to the polynomial A001 (1010 0000 0000 0001)
5. Repeat steps 3 and 4 until it is shifted right 8 times so that the entire 8 bit data is all processed
6. Repeating steps 2 through 5 for the other 8 bit data
7. The final CRC register obtained is the CRC code (the CRC code obtained is low before high).
Troubleshooting:
The meter displays an incorrect value when TTL is output. The meter may not be able to acquire data correctly due to wiring problems or communicating serial port failure. Please check whether the wiring is correct and firm, whether the serial port is occupied, and whether the serial port setting is correct..
Package List:
1 x Wired Weather Meter
Note:
1. Please check whether the package is intact, and check whether the product model is consistent with the selection;2. Do not connect the wires with electricity, check the wiring is correct before powering on;3. The sensor is a precise device, the user in the use of the user do not disassemble, with incisive objects or corrosive liquids in contact with the sensor surface, in order to avoid damage to the product. 4. the installation environment to ensure that the sensor is not damaged by the sensor;4. The installation environment to ensure that the sensor is not interfered with by other operating equipment, which may not fully comply with the common standards, such as radio, radar transmission devices, ship engines, engines, etc.;5. Do not install on the same plane as any radar scanning device, at least a distance of 2 meters should be maintained;6. avoid flocculation from surrounding buildings, e.g. trees, utility poles, tall buildings, etc., which can affect the accuracy of the product;7. Do not plug and unplug with electricity.8. When installing, you need to set the sensor to the south, the sensor out of the hole aligned with the geographical south. The mini 5 in 1 weather meter is a precise instrument, please hold it gently and do not knock it.